Solar Energy
Smart PV Controller
The SUN2000 is a three-phase grid-tied PV string inverter that converts the DC power generated by PV strings into AC power and feeds the power to the power grid.
The SUN2000 applies to grid-tied PV systems for commercial rooftops and large PV plants. Typically, a grid-tied PV system consists of the PV string, SUN2000, alternating current distribution unit (ACDU), and isolation transformer.
-
Product Description
Function
The SUN2000 is a three-phase grid-tied PV string inverter that converts the DC power generated by PV strings into AC power and feeds the power to the power grid.
Models
Figure 2-1 Designation explanation of the SUN2000-60KTL-M0
Model
Rated Output Power
Rated Output Voltage
SUN2000-50KTL-M0
50 kW
380 V/400 V/415 V
SUN2000-60KTL-M0
60 kW
380 V/400 V/480 V
SUN2000-65KTL-M0
65 kW
480 V
Networking Application
The SUN2000 applies to grid-tied PV systems for commercial rooftops and large PV plants. Typically, a grid-tied PV system consists of the PV string, SUN2000, alternating current distribution unit (ACDU), and isolation transformer.
-
Product Technical Details
Efficiency
Item
SUN2000-50KTL-M0
SUN2000-60KTL-M0
SUN2000-65KTL-M0
Maximum efficiency
98.70%
98.70% (380 V/400 V)
98.90% (480 V)
98.90%
European efficiency
98.50%
98.50% (380 V/400 V)
98.70% (480 V)
98.70%
Input
Item
SUN2000-50KTL-M0
SUN2000-60KTL-M0
SUN2000-65KTL-M0
Maximum input power
56,200 W
67,400 W
73,500 W
Maximum input voltagea
1100 V
Operating voltage rangeb
200–1000 V
Maximum input current (per MPPT)
22 A
Maximum short-circuit current (per MPPT)
30 A
Maximum SUN2000 backfeed current to the PV array
0 A
Minimum startup voltage
200 V
Full power MPPT voltage range
520–800 V
520–800 V (380 V/400 V), 600–850 V (480 V)
600–850 V
Rated input voltage
600 V (380 V/400 V), 620 V (415 V)
600 V (380 V/400 V), 720 V (480 V)
720 V
Number of inputs
12
Number of MPP trackers
6
Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage exceeds the threshold, the solar inverter may be damaged.
Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work properly.
Output
Item
SUN2000-50KTL-M0
SUN2000-60KTL-M0
SUN2000-65KTL-M0
Rated active power
50 kW
60 kW
65 kW
Maximum apparent power
55 kVA
66 kVA
72 kVA
Maximum active power (cosφ = 1)
55 kW (Can be set to 50 kW)
66 kW (Can be set to 60 kW)
72 kW
Rated output voltagea
220 V/380 V, 230 V/400 V, 240 V/415 V, 3W+(N)b+PE
220 V/380 V, 230 V/400 V, 277 V/480 V, 3W+(N)b+PE
277 V/480 V, 3W+PE
Rated output current
76 A (380 V), 72.2 A (400 V), 69.6 A (415 V)
91.2 A (380 V) 86.7 A (400 V), 72.2 A (480 V)
78.2 A
Adapted grid frequency
50 Hz/60 Hz
Maximum output current
83.6 A (380 V), 79.4 A (400 V), 76.6 A (415 V)
100 A (380 V), 95.3 A (400 V), 79.4 A (480 V)
86.7 A
Power factor
0.8 leading … 0.8 lagging
Maximum total harmonic distortion (rated power)
< 3%
Note a: The rated output voltage is determined by Grid code, which can be set on the SUN2000 app, SmartLogger, or NetEco.
Note b: Choose whether to connect the neutral wire to the SUN2000-50KTL-M0 and SUN2000-60KTL-M0 based on the application scenario. When it is used in the scenarios without neutral wires, set Output mode to Three-phase, three-wire. When it is used in the scenarios with neutral wires, set Output mode to Three-phase, four-wire.
-
Features
Smart
- Smart I-V Curve Diagnosis supported
Efficient
- Max. efficiency 98.7%
Safe
- Fuse free design
Reliable
- Type II surge arresters for DC & AC